Baumer EExGP 0,2

Baumer EExGP 0,2

Tachogenerators

  • Tachogenerator / ATEX
  • Ex-approved by ATEX II 2 G Ex db eb IIC T6 Gb
  • Low response time
  • Open circuit voltage 20…150 mV per rpm
  • Solid shaft ø11 mm
  • EURO flange B10
  • High signal quality due to patented LongLife technology
  • Recognition of sense of rotation

Reversal tolerance: ≤0,1 %
Approval: CE ATEX
Emitted interference: EN 61000-6-3
Interference immunity: EN 61000-6-2
Open-circuit voltage: 20...150 mV per rpm
Armature-circuit time-constant: <150 µs
Performance: 12 W (speed ≥5000 rpm)
Climatic test: Humid heat, constant (IEC 60068-2-3, Ca)
Calibration tolerance: ±5 %
Isolation class: B
Temperature coefficient: ± 0,06 %/K (open-circuit)
Linearity tolerance: ≤0,15 %
Ambient temperature: -20...+55 °C
Resistance: IEC 60068-2-6 Vibration 10 g, 10...2000 Hz IEC 60068-2-27 Shock 300 g, 6 ms
Corrosion protection: IEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO 12944-2
Explosion protection: II 2 G Ex db eb IIC T6 Gb (gas)
Weight approx.: 3,8 kg
Material: Aluminium die cast alloy Shaft: stainless steel
Admitted shaft load: ≤60 N axial ≤80 N radial
Rotor moment of inertia: 1,15 kgcm²
Torque: 1,5 Ncm
Protection DIN EN 60529: IP 54 (T6)
Shaft type: ø11 mm solid shaft
Size (flange): ø115 mm
Connection: Screw terminal connector

Data sheet - EExGP 0,2

  • PDF
  • 362.5 KB
Download

Data sheet - EExGP 0,2

  • PDF
  • 377.21 KB
Download

Data sheet - EExGP 0,2

  • PDF
  • 366.59 KB
Download

Certificates/licenses - EExGP 0,2 / TG 74 d EU-Type Examination Certificate

  • PDF
  • 530.56 KB
Download

Declarations of conformity - EExGP 0.2, TG 74

  • PDF
  • 246.35 KB
Download

Assembly instructions - EExGP 0,2, TG 74 d

  • PDF
  • 2.09 MB
Download

Enquire About Baumer EExGP 0,2

If you have any questions or queries please don’t hesitate to get in touch.
We aim to respond to all messages within 48 hours.

Baumer Product Catalogue

All of the Baumer products we supply can be found in the Baumer catalogue which is downloadable here